igh Accuracy Wet Dispersion Laser Particle Size Analysis
Oil Measuring Instrument Winner2000ZDE
our particle size analyzer will enable you understand your materials well, and save your time and cost. Reliable data enables scientists, researchers and engineers to evolve formulations and processes with confidence. Our products guide research
and product development, manage and control manufacturing quality, and optimize output.
Main Specification:
Model Name |
Winner2000ZDE |
Winner2000ZD(3 Gears) |
|
Standard |
ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009 |
||
Measuring Range |
0.1-300μm |
0.1-40μm /0.6-120μm/1-300μm |
|
Channels Number |
78 |
76×3 |
|
Accuracy error |
<0.5% (National Standard Sample D50 ) |
||
Repeatability error |
<0.5% (National Standard Sample D50 ) |
||
Light source |
High performance He-Ne Laser (λ= 632.8nm, P>2MW) |
||
Dispersion Method |
Ultrasonic |
Frequency:40KHz Power:60W, Time can be adjusted . |
|
Stir |
Revolutions Speed: 0-3000RPM (Adjustable) |
||
Circulate |
Rated Flow:8L/min Rated Power:10W |
||
Sample Pool |
Volume:350mL |
||
Micro- Sample Pool |
Volume: 10mL ( Optional) |
||
Operation Mode |
Full automatic software control |
||
Optical Calibration System |
Full automatic |
||
Test Speed |
<2mins for each time |
||
Volume |
L88cm×W39cm×H46cm |
||
Net Weight |
41Kg |
||
Warranty |
1 year |
Main Features:
Advanced design of light path: A patented technique of Fourier transform of converging light released the scattered light at large-scattering-angles from the restriction of the aperture of the Fourier lens. The focal length is reduced to enhance the resolution of the
instrument.
Built-in dispersing units: We carefully aligned the stirring set-up, the ultrasonic dispersing unit and the sample circulation pipes, and fixed them inside the instrument. Such a built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles, which can be observed in the
designs that these dispersing units are separated from the instruments, where the sample circulation pipes are therefore too
long, The sample will be sufficiently dispersed.
Unconstrained fitting techniques: The particle analysis software uses a unique unconstrained data fitting technique that we
developed to obtain data of unknown size distribution, this is particularly important for researchers.
Micro sample chamber (optional): The capacity of the sample chamber is as small as only 10ml. This helps with measuring
expensive/precious samples, or samples difficult to be dispersed within medium.
Modern measurement control: Users can perform all measurement procedures by simply operating on the PC and have ideal
results in a very short time.
Packaging & Shipping
Wooden box package, G.W.:50 KG. Outer dimension is L107*W578H41cm.
We would ship machine by DHL, FeDex, China express, by sea and by air.
Our Services Quality assurance
1. Strictly conforming to ISO9001-2000 quality management system,
2. Strict control from purchasing materials, process inspection to final test,
3. QC department to execute quality control regulations,
4.Only qualified components will be assembled and total equipment must be inspected completely before sale.
5, Machine will be processed preventing -shake test before delivery.
After sale service
1. We will send our technician to install instruments.( operation demo video CD will be offered also.)
2. Offer free-training service.
3. The quality assurance date is 1 year since finishing payment, Technology support in all a life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).
5. We offer the components with favorable price and perdurable maintenance.
Certifications
Company Information
JINAN WINNER PARTICLE INSTRUMENT STOCK CO., LTD. have been specialized in laser particle size analyzer since 1985, Our General Manger, Professor Ren created 1st of laser paraticle size analyzer in Jinan University, We are specialized in Laser DiffractionParticle Size Analyzer, Dynamic Light Scattering Nanometer Particle Size Analyzer,Image Particle Size Analyzer, OnlineParticle Size Analyzer,Droplet Particle Size Analyzer and Particle Counter etc.
FAQ
Purchase laser particle size analyzer need know points:
1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also.Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.
2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.
3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.
For dry dispersion model, just use compressed air as dispersion media.
In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.
If any question, you can send INQUIRY , or CHAT with us, we will be glad to service you !
Payment Terms︰ TT